Explosion Protected Crane Electric & Components
|
|
|

|
Control box
Main control box &
Hoist control box
| Rated |
Zone
1 and Zone 2
|
| Explosion protection: |
Gas -
II 2 G EEx de IIC T4 |
| Control voltage : |
42V, 230V |
| Power supply |
400V, 3 phase, 50Hz |
| Temperature range: |
-20ˇăC to +40ˇăC |
| Protection class: |
IP 55 |
| Material : |
Housing & terminal box : Sheet metal
Cover : Light metal |
| Paint : |
Textured stove-enamel,
housing : pale grey
Cover : Umber grey |
| Control : |
All hoisting, traveling motions are designed for 2
speeds |
| Cable entry : |
Via ex glands |
|
|
|
Travel drive (Brake motor)
Brake motor with brake disc
and centrifugal mass. Smooth acceleration and braking characteristics
for minimum swinging of load.
| Rated |
Zone
1 and Zone 2
|
| Explosion protection: |
Gas -
II 2 G EEx de IIB/C T4 |
| Control voltage : |
42V, 230V |
| Power supply |
3 phase, 50Hz - 230V, 380V, 400V, 415V, 500V
3 phase, 60Hz - 380V, 440V, 460V, 480V, 600V
Other voltage - on request |
| Temperature range: |
-20ˇăC to +40ˇăC
Other temperature - on request |
| Protection class: |
IP 54, Other protection - on request |
| Control : |
All hoisting, traveling motions are designed for 2
speeds |
[
Top ]
|
|
|
Control pendent
| Rated |
Zone
1 and Zone 2
Zone 21 and Zone 22
|
| Explosion protection: |
Gas -
II 2 G EEx de IIC T6
Dust -
II 2 D EEx de IIC T6 |
| Rated insulated voltage : |
500V Max. |
| Temperature range: |
-20ˇăC to +40ˇăC |
| Protection class: |
IP 66 |
| Material : |
Housing : Impact-resistant moulded
insulating material |
| Control : |
Contact elements are two-steps, this permit speedy
changeover from 'fast' to 'slow' and vice versa. |
|
|
|
Junction box
[
Top ]
|
|
|
Position switch
| Rated |
Zone
1 and Zone 2
Zone 21 and Zone 22
|
| Explosion protection: |
Gas -
II 2 G EEx de IIC T6
Dust -
II 2 D IP65 T80 ˇăC |
| Rated voltage : |
500V AC. 250V DC, Max. |
| Rated current : |
10 Amp Max. |
| Temperature range: |
- 20 ˇăC ... + 70 ˇăC (6 A) |
| Protection class: |
IP 65 |
| Material : |
Enclosure Polyamide, glass fibre-reinforced; black |
|
|
|
Isolator
| Rated |
Zone
1 and Zone 2
Zone 21 and Zone 22
|
| Explosion protection: |
Gas -
II 2 G EEx de IIC T6
Dust -
II 2 D IP65 T80 ˇăC |
| Poles |
3 pole & 6 pole |
| Rated working voltage : |
690 V AC |
| Rated current : |
16 Amp - 160 Amp |
| Temperature range: |
-20ˇăC to +40ˇăC |
| Protection class: |
IP 65 / IP 55 |
ˇˇ[
Top ]
|
|